Cleanroom System Supporting

Cleanroom System Supporting

Home /Cleanroom System Supporting /

Manual HVAC Smoke Extraction Fireproof Damper FH-70

Manual HVAC Smoke Extraction Fireproof Damper FH-70

Manual HVAC fire damper FH-70, installed in the ventilation or air-conditioning systems, usually it is open, once a fire occurs, the gas temperature of the duct arrives at 70 degrees, and then the fuse protector will be fused and the damper will close under the pull of spring. It can meet the requirement of stability and completeness in a certain time.

  • Item No :

    HVAC Duct Damper FH-70
  • Order(MOQ) :

    1*40HQ
  • Payment Term :

    30% deposit , 70% before shipping
  • Product Origin :

    CHINA
  • Color :

    RAL Color
  • Shipping Port :

    Xiamen/Qingdao/Shanghai/ShenZhen
  • Leading Time :

    15 working days after deposit

HVAC Galvanized Sheet Adjust Duct Fire Damper Motorized Fireproof and Smoke Control Damper

Manual HVAC fire damper FH-70, installed in the ventilation or air-conditioning systems, usually it is open, once a fire occurs, the gas temperature of the duct arrives at 70 degrees, and then the fuse protector will be fused and the damper will close under the pull of spring. It can meet the requirement of stability and completeness in a certain time. It can insolate smog and fire outside.

 

HVAC Smoke Extraction Fireproof Damper

 

Application

Apply to air ducts of ventilation and air-conditioning system which has smoke proofing and fireproofing requirements, especially suitable for the important buildings that can not be reset manually.

l  Using galvanized steel as material to make sure good insulation performance, and fire & corrosion resistance.

l  Duration, long service life.

l  Easy installation.

l  The flange is bent directly by the frame.

l  The valve size and color can be customized according to the customer's requirements.

l  By DC24V power to close the valve

 

HVAC Fireproof Damper

 

Damper Blade

We supplied stainless steel or aluminum damper blade as requested.

Silicone seal

The silicone seal was assembled as requested. It is wear-resisting and has high-temperature resistance.

 

FAQ

Q1:Do you have MOQ?
A1:Depends on different ideas,can be negotiated.The large the quantity is,the competitive the unit price will be.
 
Q2:Should the customers pay the delivery fee of samples?
A2:We are glad to provide a reasonable quantity of samples for your testing, but sample delivery fee should be counted on your express account or we will help check a cheaper express here.
 
Q3:When can I get a price?
A3:We usually quote whithin 24 hours after we get your inquiry.

 

Q4:How do you avoid surface scratching during container loading?
A4:We usually use metal pallet at bottom for container loading.

 

Payment terms:

T/T 30% deposit in advance, balance payment before shipment or L/C at sight

 

Delivery time:

It usually takes only 10-15 days after deposit

(depends on order specific and quantity ) 

 

Sample policy:

Free samples are available,shipping fees at clients’ expense

 

 

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
ffu hepa

Most FFU (Fan Filter Unit) assemblies are constructed using imported environmentally-friendly galvanized steel, which ensures they are rust-proof and corrosion-resistant. Additionally, the lightweight yet robust design enhances their structural integrity. The enclosure design incorporates the golden ratio, making the FFU units not only aesthetically pleasing but also ultra-thin. 

Learn More
Motorized Damper

LUSEN Motorized HVAC Duct Damper,installed in the ventilation or air-conditioning systems, usually it is open, once a fire occurs, the gas temperature of the duct arrives at 70 degrees, and then the fuse protector will be fused and the damper will close under the pull of spring. It can meet the requirement of stability and completeness in a certain time. 

Learn More
HVAC Smoke Extraction Fireproof Damper

Manual HVAC fire damper FH-70, installed in the ventilation or air-conditioning systems, usually it is open, once a fire occurs, the gas temperature of the duct arrives at 70 degrees, and then the fuse protector will be fused and the damper will close under the pull of spring. It can meet the requirement of stability and completeness in a certain time.

Learn More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

Contact